Product Name
N1206 F SERIES
Voltage
DC 32 / 63V
Characteristic
Fast Acting Type
Features
Environmentally conscious
- Pb Free, Halogen Free, Antimony Free
- REACH (SVHC), RoHS
High performance material can protect PCB against ambient temperature.
Solderability
Pre Heating : 150℃ ± 10℃, 120sec
Solder bath : 245℃ ± 5℃, 10s ± 1sec
Reflow : 260℃ ± 10℃, 10s ± 1sec
Delating
lower temperature : -40℃
higher temperature : +125℃
Agency Approvals
AGENCY
AGENCY FILE No.
AMPERE RANGE
E328408 0.50A~5.00A
E328408 0.50A~5.00A
Dimensions
Electrical Characteristics for Series
% of Ampere Rating
Ampere Rating
Opening Time
at 25℃
100% 0.50A~5.00A 4hour minimum
200% 0.50A~5.00A 5sec maximum
Device Type
Dimensions(mm) ± 0.1mm
L1
L2
W
T1
T2
C
D
E
F
G
N1206 F Series 3.2 2.4 1.6 1.0 (0.5) 2.1 0.55 1.0 2.4 0.4
Electrical Specification
Ampere
Rating
(A)
Marking
Rated
Voltage
(V)
Fusing Time (sec)
Internal
Nominal
R(mΩ)
Rated
Ambient
Temperature
Operating Temperature Range
0.50A FC 63V 5 sec maximum
at 200% rated
current 180 Body : 95℃
Contact : 70℃ -40℃
to
+125℃
0.75A FD 63V 110
1.00A FE 63V 85
1.25A FF 32V 55
1.50A FG 32V 46
1.75A FH 32V 42
2.00A FI 32V 36
2.50A FJ 32V 27
3.00A FK 32V 20
3.50A FL 32V 18
4.00A FM 32V 16
5.00A FO 32V 11
Performance Characteristics
Test Enviroment -
Ambient Temperature : 10℃ - 50℃ ,
Humidity : 45% - 85%
No
Test Item
Test Condition
Requirement
1 Resistivity
Test Temp : Ambient
It is applied for 1 hour and 15min off at 110% of rated current
Duration : 100 Hours(Endurance Test)
Measure Voltage drop. Do not exceed 10%
2 Time/Current
Characteristic Apply 200% of rated current
Fusing Time : 5 sec maximum
3 Temperature
Rising Measure the temperature at surface of device
Body : 95℃ Max
Contact : 70℃ Max
4 Cycling
Test Lower temperature : -40℃
Upper temperature : +125℃
No. of cycling Time : 5
No Open during cycling
5 Endurance
Test Test condition : Nominal ambient Temp. and Relative humidity
Test potential
1. Cycle of 1hour “ON” and 15min “OFF” at 105% rated current for 100 times.
2. After above the test, inflict 125% rated current for 1hour
The voltage drop across the fuse after the test shall not have increased by more than 10% of the value measured before test
Derating Curve
Reflow Condiction
Time / Current Characteristics |
|
|