Product Name
N4524 C SERIES
Voltage
AC 125 / 250V
Characteristic
Fast Acting Type
Features
Environmentally conscious
- Pb Free, Halogen Free, Antimony Free
- REACH (SVHC), RoHS
High performance material can protect PCB against ambient temperature.
Solderability
Pre Heating : 150℃ ± 10℃, 120sec
Solder bath : 245℃ ± 5℃, 10s ± 1sec
Reflow : 260℃ ± 10℃, 10s ± 1sec
Delating
lower temperature : -40℃
higher temperature : +125℃
Agency Approvals
AGENCY
AGENCY FILE No.
AMPERE RANGE
E328408 0.50A~5.00A
E328408 0.50A~5.00A
CA12P3129 1.00A~5.00A(250V)
SG05002-11005A~8A 1.00A~5.00A(125V/250V)
Dimensions
Electrical Characteristics for Series
% of Ampere Rating
Ampere Rating
Opening Time
at 25℃
100% 0.50A~5.00A 4hour minimum
200% 0.50A~5.00A 5sec maximum
Device Type
Dimensions(mm) ± 0.1mm
L1
L2
W
T1
T2
C
D
E
F
G
N4524 C Series 4.5 3.3 2.4 1.0 (0.5) 3.0 0.75 1.3 3.3 0.6
Electrical Specification
Ampere
Rating
(A)
Marking
Rated
Voltage
(V)
Fusing Time (sec)
Internal
Nominal
R(mΩ)
Rated
Ambient
Temperature
Operating Temperature Range
0.50A CC 125/250 5 sec maximum
at 250% rated
current 199 Body : 95℃
Contact : 70℃ -40℃
to
+125℃
0.75A CD 125/250 117
1.00A CE 125/250 68
1.25A CF 125/250 55
1.50A CG 125/250 41
1.60A CG1 125/250 39
1.75A CH 125/250 35
2.00A CI 125/250 33
2.50A CJ 125/250 27
3.00A CK 125/250 25
3.50A CL 125/250 22
4.00A CM 125/250 18
4.50A CN 125/250 15
5.00A CO 125/250 12
Performance Characteristics
Test Enviroment -
Ambient Temperature : 10℃ - 50℃ ,
Humidity : 45% - 85%
No
Test Item
Test Condition
Requirement
1 Resistivity
Test Temp : Ambient
It is applied for 1 hour and 15min off at 110% of rated current
Duration : 100 Hours(Endurance Test)
Measure Voltage drop. Do not exceed 10%
2 Time/Current
Characteristic Apply 250% of rated current
Fusing Time : 5 sec maximum
3 Temperature
Rising Measure the temperature at surface of device
Body : 95℃ Max
Contact : 70℃ Max
4 Cycling
Test Lower temperature : -40℃
Upper temperature : +125℃
No. of cycling Time : 5
No Open during cycling
5 Endurance
Test Test condition : Nominal ambient Temp. and Relative humidity
Test potential
1. Cycle of 1hour “ON” and 15min “OFF” at 105% rated current for 100 times.
2. After above the test, inflict 125% rated current for 1hour
The voltage drop across the fuse after the test shall not have increased by more than 10% of the value measured before test
Derating Curve
Reflow Condiction
Time / Current Characteristics |
![](http://img.qy6.com.cn/images/noimg.gif) |
|